Web Generator 1.0.0
ISKO
Information about air quality in the Czech Republic
Measuring programme table

Updated: 2026-02-04 03:45 CET


Basic data
Code: PPLLA
Old ISKO number: 2681
Locality: Plzen-Lochotin
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
Target of the measuring programme
Cover
container (air-conditioned)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 93 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg∙m -3 Yes Yes 0 Y A A N R A 10min 2025-04-01
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 0 O₃ [ozone] - UVABS [UV-absorption] µg∙m -3 Yes No 0 Y A A A R A 1h 2025-01-01
L1 D1 96 O₃ [ozone] - UVABS [UV-absorption] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 88 PM 1 [fine particles PM1] - OPEL [optoelectronic method] µg∙m -3 Yes Yes 0 Y A A A R A 1h 2025-04-01
L1 D1 88 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] µg∙m -3 Yes Yes 0 Y A A A A A 1h 2025-04-01
L1 D1 88 PM₁₀ [particles PM10] - OPEL [optoelectronic method] µg∙m -3 Yes Yes 0 Y A A A A A 1h 2025-04-01
L2 D2 0 INDX [Index of Air Quality Pollution] - x [unknown ] - No No 0 N N N N N N 1h 2025-04-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No No 0 N N N N N N 1h 2025-04-01
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No No 0 N N N N N N 10min 2025-04-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No No 0 N N N N N N 1h 2025-04-01
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No No 0 N N N N N N 10min 2025-04-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No No 0 N N N N N N 1h 2025-04-01
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No No 0 N N N N N N 10min 2025-04-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No No 0 N N N N N N 1h 2025-04-01
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No No 0 N N N N N N 10min 2025-04-01
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2025-04-01
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 1h 2025-04-01
L1 D1 41 T10m [temperature 10m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 1h 2025-04-01
L1 D1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg∙m -3 Yes No 0 Y A A A R A 1h 2025-01-01 2025-12-31
L1 D1 0 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg∙m -3 Yes No 0 Y A A A R A 1h 2025-01-01 2025-12-31
L1 D1 0 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg∙m -3 Yes No 0 Y A A A R A 1h 2025-01-01 2025-12-31
L1 D1 0 PM₂.₅ [fine particles PM2.5] - OPEL [optoelectronic method] µg∙m -3 Yes No 0 Y N A A A A 1h 2025-01-01 2025-12-31
L1 D1 0 PM₁₀ [particles PM10] - OPEL [optoelectronic method] µg∙m -3 Yes No 0 Y N A A A A 1h 2025-01-01 2025-12-31
List of laboratories
Laboratory number 1 (L1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377256641
 
E-mail: tomas.fory@chmi.cz
Laboratory number 2 (L2) unknown

Tel.:
 
E-mail:
List of data suppliers
Supplier number 1 (D1) ČHMÚ - pob. Plzeň
Mozartova 41
323 00 Plzeň
Tel.: 377 256 641
 
E-mail: tomas.fory@chmi.cz
Supplier number 2 (D2) unknown

Tel.:
 
E-mail: